Putting it all Together
This section describes how to integrate the new features of the production readout software
with the EPICS archiver so that you can log control data to event files.
Briefly you will:
- [ ]Startup the Readout program.
- [ ]Source a script into the readout program to allow the epics archiver to connect as
a TclServer client.
- [ ]Start the epics archiver.
- [ ]Source a script into the readout program that will make all of the epics variables
runvar's which in turn will ensure they are periodically logged to the event file.
Report documentation errors to
Ron Fox
(fox@nscl.msu.edu)or
NSCL's Bugzilla page